MCIAT chartered drawings · Fixed fees across all 33 London boroughs
Services
Areas
Guides
ProcessOur promiseFAQ
Free approval reportGet my free quote020 7864 7245
Rear extension drawings in Coaley and Uley — a glazed single-storey rear extension opening to the garden
Coaley and Uley · Rear Extension Drawings & Planning

Rear extension drawings in Coaley and Uley

Back-of-house extension drawings for Coaley and Uley homes — the glazed kitchen-diner across the rear, drawn to Stroud District Council's depth and daylight limits, delivered in days and revised free until your decision, with a free approval-odds check first.

★★★★★ Rated 4.9/5 by London homeowners96% approval rate · 2,400+ drawings delivered
Share

Coaley and Uley planning decisions and design rules

Stroud District Council granted 92% of the householder planning decisions it made in its latest published year — 5 points above the 87% England-wide householder average. Coaley and Uley contains Nympsfield, Uley conservation areas, so materials, fenestration and roof form are assessed against the appraisal, which is where a policy-literate drawing pack earns its keep. Its dominant Victorian (1837–1901) and postwar (1945–1970) housing stock sets the design brief on most streets.

Before permission is required, Class B allows 40m³ of added loft volume on a terrace and 50m³ on a semi or detached house, and Class A allows a 3m single-storey rear extension on a terrace or 4m on a detached house. In conservation areas such as Nympsfield and Uley those rights are removed, so we confirm your exact address before a line is drawn. A validated householder application in Coaley and Uley is determined against an 8-week statutory target.

Nympsfield (designated conservation area), Uley (designated conservation area), Coaley (civil parish within Coaley and Uley), Nympsfield (civil parish within Coaley and Uley), Owlpen (civil parish within Coaley and Uley) and Uley (civil parish within Coaley and Uley) — these are the Coaley and Uley pockets our drawings cover most. Heritage designations here include Nympsfield and Uley. Stroud District Council weighs each proposal against Stroud District Council's adopted local plan and its householder design guidance, where the 1,060 homes here are 39% pre-1900, 10% 1945-1954, 9% 1965-1972, which is what sets the realistic roof and rear-projection options. On roofs the borough is steeply pitched slate roofs, valley gutters and party parapets typical of pre-1900 building and simple gabled and hipped roofs typical of early postwar building, over Victorian and earlier houses (39% of 1,060 homes), early postwar houses (10%) and late-1960s and early-1970s houses (9%).

Why a Coaley and Uley scheme is judged on Coaley and Uley terms

What is permitted in Coaley and Uley turns on designation first, so that is where we start: Nympsfield (designated conservation area) and Uley (designated conservation area). Inside those boundaries permitted development is curtailed and Stroud District Council assesses materials, window detail and roof form against the area's own appraisal, so a scheme that would be waved through two streets away can need a full application here.

Beyond the designated areas, Coaley and Uley takes in Coaley, Nympsfield, Owlpen and Uley. No Article 4 direction is recorded for Stroud District Council, but Coaley and Uley's 2 conservation areas still limit permitted development on those streets.

On stock, Coaley and Uley is Victorian and earlier houses (39% of 1,060 homes), early postwar houses (10%) and late-1960s and early-1970s houses (9%) — which is why steeply pitched slate roofs, valley gutters and party parapets typical of pre-1900 building and simple gabled and hipped roofs typical of early postwar building govern what a loft or rear projection can realistically be. Stroud District Council decided 537 householder applications in the latest published year and granted 92%, with 73% issued inside the eight-week target. We draw to that record rather than to a national average.

The full build-period split for Coaley and Uley runs pre-1900 39% (410 homes), 1900-1918 2% (20 homes), 1919-1929 4% (40 homes), 1930-1939 5% (50 homes), 1945-1954 10% (110 homes), 1955-1964 5% (50 homes), 1965-1972 9% (100 homes), 1973-1982 9% (100 homes), 1983-1992 4% (40 homes), 1993-1999 4% (40 homes) and 2000-2008 3% (30 homes). That distribution is why pre-1900 detailing dominates the drawings here, and it is measured from council-tax records rather than assumed from the street name.

Stroud District Council also decides for Berkeley Vale, Dursley, Painswick and Upton, Stroud Central, Bisley, Chalford, Kingswood and Minchinhampton, so a decision in Coaley and Uley sits inside a wider pattern of decisions we track across the same authority — useful when an officer cites a precedent from the next area over.

Coaley and Uley by the published data

Published figures for Coaley and Uley and Stroud District Council. These are the numbers that decide what is realistic on your street, so we work from them rather than from national averages.

MeasureCoaley and Uley
Dwellings recorded1,060
Built pre-1900410 (39%)
Built 1900-191820 (2%)
Built 1919-192940 (4%)
Built 1930-193950 (5%)
Built 1945-1954110 (10%)
Built 1955-196450 (5%)
Built 1965-1972100 (9%)
Built 1973-1982100 (9%)
Built 1983-199240 (4%)
Built 1993-199940 (4%)
Built 2000-200830 (3%)
Built before 191941%
Built 1919–19398%
Built 1945–200844%
Conservation areas in Coaley and Uley2 (Nympsfield, Uley)
Conservation areas district-wide41
Article 4 directions recorded0
Householder applications decided537
Householder applications granted92%
Decided within 8 weeks73%

Dwelling stock from VOA council-tax data at 31 March 2025; conservation-area and Article 4 counts from planning.data.gov.uk (MHCLG); decision figures are Stroud District Council's own, from MHCLG live table PS2 for the year to 31 March 2026.

Rear extensions drawn to Stroud District Council's depth and daylight limits

The rear extension is the workhorse of Coaley and Uley home improvement — it is how a dark back kitchen becomes an open family room facing the garden. Because the borough is built largely from Victorian and earlier houses (39% of 1,060 homes), early postwar houses (10%) and late-1960s and early-1970s houses (9%), most back walls sit close to a neighbour on at least one side, and that proximity, not the design, is what Stroud District Council scrutinises. The council reads the proposal against Stroud District Council's adopted local plan and its householder design guidance, and the first line an officer draws is the 45-degree splay from the neighbour's nearest window.

So the drawings live or die on geometry. We set the depth against the exact permitted-development figure, hold the eaves and the flat-roof or lantern build-up under the 4-metre height ceiling, and show the projection tested against both the 45-degree plan angle and the 25-degree section angle to the neighbouring windows. Coaley and Uley contains Nympsfield, Uley conservation areas, so materials, fenestration and roof form are assessed against the appraisal, so the rear elevation is composed around it rather than corrected after an objection.

Where the property sits in a conservation area — Nympsfield and Uley among Coaley and Uley's — the larger-home extension route is switched off and even a modest rear addition needs consent. No Article 4 direction is recorded for Stroud District Council, but Coaley and Uley's 2 conservation areas still limit permitted development on those streets. We confirm the designation before the survey.

Isometric rear extension drawing for a Coaley and Uley house

Does a rear extension need planning permission in Coaley and Uley?

Many single-storey rear extensions in Coaley and Uley are permitted development and need no application. You will normally need to apply to Stroud District Council, or use the larger-home prior-approval route, if any of these apply:

  • The extension projects more than 3 metres from the original rear wall on a terrace or semi (4 metres on a detached house)
  • You want 6 metres (terrace/semi) or 8 metres (detached) — allowed only via the larger-home prior-approval scheme, with neighbour consultation
  • It is a two-storey rear extension, or any part is higher than 4 metres
  • A two-storey rear extension would come within 7 metres of the rear boundary
  • Your home is in a conservation area such as Nympsfield and Uley, where the larger-home route does not apply

Coaley and Uley rear extension approval rates — live from council data

Below is Stroud District Council's real householder decision record, taken from official planning statistics and refreshed as new data lands. Stroud District Council granted 92% of its householder applications in the year to 31 March 2026, and Nympsfield shapes what is approved here. Rear extensions turn most often on neighbour daylight and depth, so a drawing pack that proves those tests upfront is decided faster and refused less often than a DIY submission.

Source: MHCLG planning application statistics (householder decisions, England, 1 April 2025 - 31 March 2026). Compare every borough on our London approval-rate league table.

92%householder applications approved in Stroud
87%national average — Stroud is 5 points above the national average

Ready for drawings your council will approve?

Tell us about your project and get a fixed, no-obligation quote back within one working day. If you don't need planning permission at all, we'll tell you that too — for free.

Get your free fixed quote

60 seconds now. A fixed, no-obligation quote back within one working day — and we'll tell you if you don't even need planning.

No obligation · No spam · Reply within 1 working day

What rear extensions get approved in Coaley and Uley

Across Nympsfield, Uley and Coaley, the approved rear extension is typically a single-storey glazed box within the depth limit, roofed either flat with a lantern or in a shallow mono-pitch, and finished in brick or render to match the host wall. On the borough's victorian and earlier houses (39% of 1,060 homes), keeping the projection to the permitted-development figure often avoids an application entirely; where owners want the full 6 metres, the larger-home route succeeds when the neighbour-consultation period passes without a sustained objection.

The 1,060 homes here are 39% pre-1900, 10% 1945-1954, 9% 1965-1972, which is what sets the realistic roof and rear-projection options. We keep the extension inside the daylight splays, set any glazed roof below the first-floor cill, and retain the garden depth Stroud District Council expects — so the back elevation answers the amenity case before a neighbour can lodge one. Two-storey rear extensions we draw with the 7-metre boundary gap and privacy screening resolved on the plan.

Open-plan living space created by a rear extension in Coaley and Uley

Rear extensions across Coaley and Uley

We draw rear extensions on every street in the borough. A few of the neighbourhoods where Coaley and Uley back-of-house projects come up most often:

Nympsfield

Rear extension drawings for Nympsfield's designated conservation area — depth-checked, daylight-tested and drawn to Stroud District Council's guidance.

Uley

Rear extension drawings for Uley's designated conservation area — depth-checked, daylight-tested and drawn to Stroud District Council's guidance.

Coaley

Rear extension drawings for Coaley's civil parish within Coaley and Uley — depth-checked, daylight-tested and drawn to Stroud District Council's guidance.

Nympsfield

Rear extension drawings for Nympsfield's civil parish within Coaley and Uley — depth-checked, daylight-tested and drawn to Stroud District Council's guidance.

Owlpen

Rear extension drawings for Owlpen's civil parish within Coaley and Uley — depth-checked, daylight-tested and drawn to Stroud District Council's guidance.

Uley

Rear extension drawings for Uley's civil parish within Coaley and Uley — depth-checked, daylight-tested and drawn to Stroud District Council's guidance.

Which rear extension route suits your Coaley and Uley house?

How far you can extend at the back in Coaley and Uley depends on your house type and the route you take. This is how the options compare.

RouteDepth allowedConsent neededWhat Stroud District Council checks
Standard permitted development3m terrace/semi · 4m detachedLawful development certificate (optional)Depth, 4m height, materials
Larger-home prior approval6m terrace/semi · 8m detachedPrior-approval notice + neighbour consultationNeighbour objections on amenity
Full householder applicationBeyond the above, or two-storeyFull planning permissionDaylight (45°/25°), bulk, garden retained
Conservation areaCase by caseFull planning permissionCharacter, roof form, boundary treatment

The larger-home route is switched off on designated land — conservation areas such as Nympsfield and Uley and Article 4 streets need a full application.

Four steps to an approved Coaley and Uley rear extension

A fixed process built around how Stroud District Council validates and decides rear-extension applications — most drawings are submission-ready within seven days of survey.

  1. 1

    Free approval check

    Send us your Coaley and Uley postcode and house type. We confirm your conservation and Article 4 status, how much rear-extension depth you have under permitted development, and score your odds against live Stroud District Council decisions.

  2. 2

    Measured survey

    We measure the original rear wall, floor and eaves levels, side and rear boundary distances and the neighbours' window positions — the numbers the depth limit and daylight splays depend on.

  3. 3

    Rear extension design & drawings

    Chartered designers develop the single or two-storey rear extension to your brief, drawn inside the permitted-development limits or to Stroud District Council's extension design guidance, with the daylight angles shown.

  4. 4

    Submission & follow-through

    We submit the certificate, prior-approval notice or application, handle validation and case-officer queries, and revise the drawings free until Stroud District Council issues its decision.

Frequently asked questions

Does a rear extension need planning permission in Coaley and Uley?

Often not. A single-storey rear extension up to 3 metres deep on a terrace or semi, or 4 metres on a detached house, and no higher than 4 metres, is usually permitted development in Coaley and Uley. You will need to involve Stroud District Council for anything deeper via the larger-home route, for two-storey rear extensions, and for any rear extension in a conservation area such as Nympsfield and Uley, where those permitted-development rights fall away.

How far can I extend to the rear in Coaley and Uley under the 6-metre rule?

The larger-home extension scheme lets a single-storey rear extension reach 6 metres on a terrace or semi, or 8 metres on a detached house — double the standard allowance. It is not automatic: you submit a prior-approval notification to Stroud District Council, neighbours are consulted, and if one objects on amenity grounds the council rules on it. It also does not apply on designated land such as Coaley and Uley's conservation areas.

What is the 45-degree rule for rear extensions in Coaley and Uley?

It is the daylight test Stroud District Council applies to protect neighbours. Drawn on plan, a line at 45 degrees from the midpoint of the neighbour's nearest ground-floor window should not be crossed by your extension; a companion 25-degree line is checked in section. If the projection breaches it, the extension is likely to be shortened or refused, so we test and prove it on the drawings before submission. This applies to your Coaley and Uley address specifically.

Can I build a two-storey rear extension in Coaley and Uley?

A two-storey rear extension almost always needs a full householder application to Stroud District Council, as it sits outside permitted development on most homes. The council checks that it stays at least 7 metres from the rear boundary, does not overbear the neighbours and avoids new overlooking. We resolve the boundary gap, privacy and daylight on the plans so the application is decided on its merits. This applies to your Coaley and Uley address specifically.

Do I need a party wall agreement for a rear extension in Coaley and Uley?

Frequently, yes. If the rear extension involves work to a shared wall, building up to the boundary, or excavating foundations near a neighbour's structure, the Party Wall etc. Act applies and you must serve notice — this is separate from Stroud District Council's planning decision. We flag it early and can prepare the drawings a party-wall surveyor needs alongside the planning set. This applies to your Coaley and Uley address specifically.

How much do rear extension drawings in Coaley and Uley cost?

We price each Coaley and Uley rear extension on its own footprint and send a fixed, no-obligation quote within one working day. It covers the full drawing pack with free revisions until Stroud District Council approves, and we confirm at the outset whether your extension is permitted development, needs prior approval, or a full application. Call 020 7864 7245 to begin.

Planning approval report

Know your approval odds before you spend a penny on drawings

Answer five quick questions and get a free planning score for your exact address — instantly. Then, if you want the full picture, unlock the detailed analysis: your council's live approval rates, local precedents, constraints on your street and a step-by-step route to permission.

Rear extension drawings across Stroud

Same fixed quotes, same fast drawings — wherever your project is.

Other planning services in Coaley and Uley