Larger home extension prior approval in Bere Ferrers — a deep single-storey rear extension to a house
Bere Ferrers · Prior Approval & Neighbour Consultation

Larger home extension prior approval in Bere Ferrers

The fast route to a deep single-storey rear extension in Bere Ferrers — up to 6 metres on an attached house or 8 on a detached one — via West Devon Borough Council's prior approval scheme rather than a full planning application.

★★★★★ Rated 4.9/5 by London homeowners96% approval rate · 2,400+ drawings delivered
Share

Bere Ferrers householder planning by the numbers

West Devon Borough Council granted 93% of the householder planning decisions it made in its latest published year — 6 points above the 87% England-wide householder average. Bere Ferrers contains Bere Alston, Bere Ferrers, Tavistock and Bere Alston Railway Line conservation areas (Bere Alston designated 1992), so materials, fenestration and roof form are assessed against the appraisal, which is where a policy-literate drawing pack earns its keep. Its dominant Victorian (1837–1901) and postwar (1945–1970) housing stock sets the design brief on most streets.

Under Class B, a rear dormer stays permitted development up to 40m³ of added roof volume on a terrace or 50m³ on a semi-detached or detached house, while Class A allows a single-storey rear extension of 3m beyond the original rear wall on a terrace and 4m on a detached house before a full application is needed. In conservation areas such as Bere Alston, Bere Ferrers and Tavistock and Bere Alston Railway Line those rights are removed, so we confirm your exact address before a line is drawn. A validated householder application in Bere Ferrers is determined against an 8-week statutory target.

Bere Alston (conservation area designated in 1992), Bere Ferrers (conservation area designated in 1979), Tavistock and Bere Alston Railway Line (conservation area designated in 1991), Weir Quay (conservation area designated in 1991) and Gulworthy (civil parish within Bere Ferrers) — these are the Bere Ferrers pockets our drawings cover most. Heritage designations here include Bere Alston, Bere Ferrers, Tavistock and Bere Alston Railway Line and Weir Quay. West Devon Borough Council weighs each proposal against West Devon Borough Council's development plan and the design policies it applies to householder applications, where the 1,500 homes here are 30% pre-1900, 14% 1965-1972, 11% 1973-1982, which is what sets the realistic roof and rear-projection options. On roofs the borough is steeply pitched slate roofs, valley gutters and party parapets typical of pre-1900 building and shallow-pitched roofs and integral garages typical of that period's building, over Victorian and earlier houses (30% of 1,500 homes), late-1960s and early-1970s houses (14%) and 1970s and early-1980s houses (11%).

What actually constrains a project in Bere Ferrers

Bere Ferrers's designated heritage is specific, and it is the first thing we check against your address: Bere Alston (conservation area designated in 1992), Bere Ferrers (conservation area designated in 1979), Tavistock and Bere Alston Railway Line (conservation area designated in 1991) and Weir Quay (conservation area designated in 1991). Inside those boundaries permitted development is curtailed and West Devon Borough Council assesses materials, window detail and roof form against the area's own appraisal, so a scheme that would be waved through two streets away can need a full application here.

Beyond the designated areas, Bere Ferrers takes in Gulworthy. No Article 4 direction is recorded for West Devon Borough Council, but Bere Ferrers's 4 conservation areas still limit permitted development on those streets.

On stock, Bere Ferrers is Victorian and earlier houses (30% of 1,500 homes), late-1960s and early-1970s houses (14%) and 1970s and early-1980s houses (11%) — which is why steeply pitched slate roofs, valley gutters and party parapets typical of pre-1900 building and shallow-pitched roofs and integral garages typical of that period's building govern what a loft or rear projection can realistically be. West Devon Borough Council decided 130 householder applications in the latest published year and granted 93%, with 62% issued inside the eight-week target. Those are the numbers our drawings are prepared against.

The full build-period split for Bere Ferrers runs pre-1900 30% (450 homes), 1900-1918 1% (20 homes), 1919-1929 3% (50 homes), 1930-1939 5% (80 homes), 1945-1954 5% (80 homes), 1955-1964 8% (120 homes), 1965-1972 14% (210 homes), 1973-1982 11% (170 homes), 1983-1992 6% (90 homes), 1993-1999 5% (70 homes) and 2000-2008 5% (70 homes). That distribution is why pre-1900 detailing dominates the drawings here, and it is measured from council-tax records rather than assumed from the street name.

West Devon Borough Council also decides for Buckland Monachorum, Exbourne, Hatherleigh, Milton Ford, Okehampton South, Tamarside and Tavistock South East, so a decision in Bere Ferrers sits inside a wider pattern of decisions we track across the same authority — useful when an officer cites a precedent from the next area over.

Bere Ferrers in numbers — housing stock and planning decisions

Published figures for Bere Ferrers and West Devon Borough Council. These are the numbers that decide what is realistic on your street, so we work from them rather than from national averages.

MeasureBere Ferrers
Dwellings recorded1,500
Built pre-1900450 (30%)
Built 1900-191820 (1%)
Built 1919-192950 (3%)
Built 1930-193980 (5%)
Built 1945-195480 (5%)
Built 1955-1964120 (8%)
Built 1965-1972210 (14%)
Built 1973-1982170 (11%)
Built 1983-199290 (6%)
Built 1993-199970 (5%)
Built 2000-200870 (5%)
Built before 191931%
Built 1919–19399%
Built 1945–200854%
Conservation areas in Bere Ferrers4 (Bere Alston, Bere Ferrers…)
Conservation areas district-wide24
Article 4 directions recorded0
Householder applications decided130
Householder applications granted93%
Decided within 8 weeks62%

Dwelling stock from VOA council-tax data at 31 March 2025; conservation-area and Article 4 counts from planning.data.gov.uk (MHCLG); decision figures are West Devon Borough Council's own, from MHCLG live table PS2 for the year to 31 March 2026.

How the prior approval route works in Bere Ferrers

The ordinary Class A limits stop a single-storey rear extension at 3 metres on an attached house and 4 on a detached one. The larger home extension scheme doubles both, on condition that the council is told first. That notification is not an application for permission — the council cannot refuse on design, materials or policy grounds. It can only consider the effect on the amenity of adjoining premises, and only if a neighbour actually objects during the 21-day consultation.

The other conditions still apply and are strict: single storey only, no higher than 4 metres, eaves no higher than the existing eaves, and no more than half the land around the original house covered. It is not available on designated land, so a house in a conservation area such as Bere Alston and Bere Ferrers cannot use it at all. Materials must be similar to the existing house, and the extension must not include a veranda, balcony or raised platform.

Bere Ferrers is largely Victorian and earlier houses (30% of 1,500 homes), late-1960s and early-1970s houses (14%) and 1970s and early-1980s houses (11%). Bere Ferrers contains Bere Alston, Bere Ferrers, Tavistock and Bere Alston Railway Line conservation areas (Bere Alston designated 1992), so materials, fenestration and roof form are assessed against the appraisal, which matters here because an objecting neighbour puts amenity squarely in front of a case officer. No Article 4 direction is recorded for West Devon Borough Council, but Bere Ferrers's 4 conservation areas still limit permitted development on those streets.

Isometric drawing of a deep rear extension in Bere Ferrers

Does your Bere Ferrers extension qualify for prior approval?

The scheme is available where all of these hold. Fail any one and it is a full application to West Devon Borough Council instead:

  • The extension is single storey and rear-facing
  • It projects no more than 6 metres on a terraced or semi-detached house, or 8 metres on a detached house
  • It is no more than 4 metres high, with eaves no higher than the existing eaves
  • The property is a house, not a flat or maisonette
  • The property is not on designated land — the scheme is unavailable in conservation areas such as Bere Alston and Bere Ferrers
  • No more than half the land around the original house is covered by buildings
  • The materials are similar in appearance to the existing house
  • You notify the council BEFORE building — retrospective use of the scheme is not possible

Bere Ferrers householder decisions — live from council data

Below is West Devon Borough Council's real householder decision record, drawn from official planning statistics and refreshed as new data lands. West Devon Borough Council granted 93% of its householder applications in the year to 31 March 2026, and Bere Alston shapes what is approved here. Prior approval turns on neighbour amenity alone, so the drawings that matter are the ones showing the relationship to the boundary.

Source: MHCLG planning application statistics (householder decisions, England, 1 April 2025 - 31 March 2026). Compare every borough on our London approval-rate league table.

93%householder applications approved in West Devon
87%national average — West Devon is 6 points above the national average

Ready for drawings your council will approve?

Tell us about your project and get a fixed, no-obligation quote back within one working day. If you don't need planning permission at all, we'll tell you that too — for free.

Get your free fixed quote

60 seconds now. A fixed, no-obligation quote back within one working day — and we'll tell you if you don't even need planning.

No obligation · No spam · Reply within 1 working day

What gets through prior approval in Bere Ferrers

Across Bere Alston, Bere Ferrers and Tavistock and Bere Alston Railway Line, the notifications that clear without objection are the ones that treat the neighbour as the audience. We show the extension in section against the boundary, demonstrate the 45-degree daylight relationship to the nearest habitable window, and where the plot is tight we taper the depth away from the boundary rather than running the full 6 metres to the fence.

The 1,500 homes here are 30% pre-1900, 14% 1965-1972, 11% 1973-1982, which is what sets the realistic roof and rear-projection options. Where an objection does arrive, the council's assessment is narrow: loss of light, outlook and overbearing effect on the adjoining property, nothing else. A pack that has already answered those three points on the drawings usually survives an objection, whereas one that leaves them to the officer's imagination usually does not.

Deep single-storey rear extension to a house in Bere Ferrers

Larger home extensions across Bere Ferrers

We prepare prior-approval notifications across Bere Ferrers. A few of the areas where deep rear extensions come up most often:

Bere Alston

Prior approval drawings for Bere Alston — conservation area designated in 1992 — dimensioned to the 6m and 8m limits and prepared for West Devon Borough Council's neighbour consultation.

Bere Ferrers

Prior approval drawings for Bere Ferrers — conservation area designated in 1979 — dimensioned to the 6m and 8m limits and prepared for West Devon Borough Council's neighbour consultation.

Tavistock and Bere Alston Railway Line

Prior approval drawings for Tavistock and Bere Alston Railway Line — conservation area designated in 1991 — dimensioned to the 6m and 8m limits and prepared for West Devon Borough Council's neighbour consultation.

Weir Quay

Prior approval drawings for Weir Quay — conservation area designated in 1991 — dimensioned to the 6m and 8m limits and prepared for West Devon Borough Council's neighbour consultation.

Gulworthy

Prior approval drawings for Gulworthy — civil parish within Bere Ferrers — dimensioned to the 6m and 8m limits and prepared for West Devon Borough Council's neighbour consultation.

Prior approval or full application in Bere Ferrers?

Same extension, two routes, very different tests.

RouteDepth allowedWhat the council may considerTimescale
Ordinary Class A permitted development3m attached / 4m detachedNothing — no application neededImmediate
Larger home extension prior approval6m attached / 8m detachedAmenity of adjoining premises, only if a neighbour objects21-day consultation, 42-day determination
Full householder applicationNo fixed limitDesign, materials, policy, amenity, everything8-week target
Any of these on designated land3m / 4m onlyPrior approval scheme unavailableFull application beyond the limits

Limits and procedure from the GPDO 2015, Schedule 2, Part 1, Class A and paragraph A.4, made permanent by amendment in 2019.

Four steps to prior approval in Bere Ferrers

A process built around the 21-day consultation, which is where these schemes are won or lost.

  1. 1

    Free eligibility check

    Send us your Bere Ferrers postcode and house type. We confirm whether the property is on designated land, whether the scheme is available, and what depth you can realistically take.

  2. 2

    Measured survey

    We measure the original rear wall, eaves height, boundary distances and the neighbouring windows that the amenity assessment will turn on.

  3. 3

    Notification pack

    We draw the extension to the 6m or 8m limit with the boundary relationship shown in section, and prepare the written description and adjoining-owner details West Devon Borough Council needs to start the consultation.

  4. 4

    Consultation & follow-through

    We submit, track the 21-day consultation and the 42-day determination, respond to any objection on amenity grounds, and revise free until the decision.

Frequently asked questions

How deep can a rear extension be in Bere Ferrers without planning permission?

Three metres on a terraced or semi-detached house and four on a detached one under ordinary permitted development. Under the larger home extension prior approval scheme those double to six and eight metres, provided you notify West Devon Borough Council before starting and the conditions on height, materials and land coverage are met. The scheme is not available on designated land. This applies to your Bere Ferrers address specifically.

What is prior approval for a larger home extension in Bere Ferrers?

It is a notification, not an application for permission. You tell West Devon Borough Council what you intend to build, it writes to the adjoining owners, and they have 21 days to object. If nobody objects, you may build. If someone does, the council assesses the effect on the amenity of adjoining premises and must decide within 42 days. Design and policy are not in scope. This applies to your Bere Ferrers address specifically.

What happens if my neighbour objects in Bere Ferrers?

The council then considers the impact on the amenity of the adjoining property — loss of light, loss of outlook, and overbearing effect — and nothing else. It cannot refuse because it dislikes the design or the materials. We prepare the drawings so those three questions are already answered in section and on the site plan, which is what usually carries an objected scheme through. This applies to your Bere Ferrers address specifically. West Devon Borough Council is the decision-maker.

Can I use prior approval in a Bere Ferrers conservation area?

No. The larger home extension scheme is unavailable on designated land, which includes conservation areas such as Bere Alston and Bere Ferrers, national landscapes, national parks and world heritage sites. On those properties the ordinary 3-metre and 4-metre limits apply, and anything deeper needs a full householder application to West Devon Borough Council.

How long does prior approval take in Bere Ferrers?

Twenty-one days for the neighbour consultation, and a maximum of 42 days from a valid submission for the council to determine it. If the council does not respond within 42 days you may proceed as notified. That deadline is the scheme's real advantage over a full application, and it is why validation completeness matters so much. This applies to your Bere Ferrers address specifically. West Devon Borough Council is the decision-maker.

Do I still need building regulations approval in Bere Ferrers?

Yes — always. Prior approval deals only with the planning position. A 6-metre rear extension still needs building control approval for foundations, structure, drainage, thermal performance and fire safety, and the beam over the opening into the existing house needs designing and calculating. We prepare both sets so the notified scheme is the buildable one. This applies to your Bere Ferrers address specifically. West Devon Borough Council is the decision-maker.

How much do prior approval drawings in Bere Ferrers cost?

We quote each Bere Ferrers scheme individually, because plot shape and the boundary relationship drive the work, and send a fixed, no-obligation quote within one working day. It covers the notification pack and free revisions until West Devon Borough Council determines it. Call 020 7864 7245 to start.

Planning approval report

Know your approval odds before you spend a penny on drawings

Answer five quick questions and get a free planning score for your exact address — instantly. Then, if you want the full picture, unlock the detailed analysis: your council's live approval rates, local precedents, constraints on your street and a step-by-step route to permission.

Larger home extension prior approval across West Devon

Same fixed quotes, same fast drawings — wherever your project is.

Other planning services in Bere Ferrers